- Under 29 CFR 1910.399 for electrical work, a qualified person is one who has received training in, and has demonstrated skills and knowledge of, the construction and operation of electric equipment and installations and the hazards involved. Value: A person trained in, and demonstrated skilled and knowledgeable about, the construction and operation of electric equipment and installations and the hazards involved..
- Under 29 CFR 1910.332(b)(3), qualified persons permitted to work on or near exposed energized parts must be trained to identify exposed live parts, to determine their nominal voltage and to know the clearance distances that apply.
Elsewhere in the family
- Digital multimeter related entry on Test Instrument Reference
- Voltage detector related entry on Test Instrument Reference
- Proving unit related entry on Test Instrument Reference
- Insulating glove tester related entry on Test Instrument Reference
- Live-line tool (hot stick) tester related entry on Test Instrument Reference
- Qualified person related entry on Arc Flash Reference
Sources
- 29 CFR 1910.332, 1910.332 - Training, current edition, OSHA. Regulation text. Held as: Government work. Agency copy of 29 CFR 1910.332
- 29 CFR 1910.399, 1910.399 - Definitions applicable to this subpart, current edition, OSHA. Regulation text. Held as: Government work. Agency copy of 29 CFR 1910.399
Also stated in
- EM 385-1-1, section 11-3.b(6), page 208, the ellipsis drops item (e) on job safety planning, which sits on the next page (15 March 2024).
Read the reference passage
11-3. Personnel Required Qualification/Training. b. Qualified Persons (QPs), Electrical
"QPs that perform work within the limited approach boundary must, at a minimum, also be trained on the following: (a) The skills and techniques necessary to distinguish exposed energized live parts from other parts of electrical equipment. (b) The skills and techniques necessary to determine the nominal voltage of exposed live parts. (c) Approach distances specified for personnel in tables 11-1, 11-2, 11-3 and the corresponding voltages to which the QP will be exposed. (d) Minimum clearances specified for vehicular and mechanical equipment in table 11-4. [...]"
EM 385-1-1, section 11-3.b(6), page 208, the ellipsis drops item (e) on job safety planning, which sits on the next page, 15 March 2024. Agency copy of EM 385-1-1
The current standard governs; this passage is a public-domain description of the practice dated 15 March 2024.
Changelog (4 entries)
| Date | Revision | Change |
|---|---|---|
| 2026-10-13 | created (cert.osha-qualified-person.definition) | |
| 2026-10-13 | reviewed (cert.osha-qualified-person.definition) | |
| 2026-10-13 | created (cert.osha-qualified-person.training) | |
| 2026-10-13 | reviewed (cert.osha-qualified-person.training) |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Osha qualified person." Electrical Testing Reference. 2026-10-13. https://www.electricaltestingreference.com/certification/osha-qualified-person/.
Electrical Testing Reference, Osha qualified person (Oct. 13, 2026), https://www.electricaltestingreference.com/certification/osha-qualified-person/.
@misc{etr-certification-osha-qualified-person,
title = {Osha qualified person},
howpublished = {\url{https://www.electricaltestingreference.com/certification/osha-qualified-person/}},
organization = {Electrical Testing Reference},
publisher = {Electrical Testing Reference},
year = {2026},
note = {last substantive change 2026-10-13}
}{{cite web |title=Osha qualified person |website=Electrical Testing Reference |publisher=Electrical Testing Reference |url=https://www.electricaltestingreference.com/certification/osha-qualified-person/ |date=2026-10-13 |access-date=}}