Data record tests.insulation-resistance.discharge
Review status: Unreviewed
IEEE 43-2013 requires the winding to be discharged before the test and, afterward, grounded through a current-limiting resistor for a period that it relates to how long the voltage was applied.
- Subject
- Insulation Resistance (Test methods)
- Source
- IEEE 43-2013, clause 4, 5.5, Recommended Practice for Testing Insulation Resistance of Electric Machinery, IEEE. Publisher page
- Verified on
- 2026-10-13
- Review status
- Unreviewed
- Confidence
- High
History
| Date | Change | Reason | By |
|---|---|---|---|
| 2026-10-13 | created | method fact restated from the licensed-copy digest (Task 10 exemplars) | agent |
| 2026-10-13 | superseded | superseded by tests.insulation-resistance.discharge-practice (fresh-context review task-10-exemplars-review.md) | agent |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
Plain
"Data record tests.insulation-resistance.discharge." Electrical Testing Reference. 2026-10-13. https://www.electricaltestingreference.com/data/tests.insulation-resistance.discharge/.
Legal (Bluebook, internet source)
Electrical Testing Reference, Data record tests.insulation-resistance.discharge (Oct. 13, 2026), https://www.electricaltestingreference.com/data/tests.insulation-resistance.discharge/.
BibTeX
@misc{etr-data-tests-insulation-resistance-discharge,
title = {Data record tests.insulation-resistance.discharge},
howpublished = {\url{https://www.electricaltestingreference.com/data/tests.insulation-resistance.discharge/}},
organization = {Electrical Testing Reference},
publisher = {Electrical Testing Reference},
year = {2026},
note = {last substantive change 2026-10-13}
} Wikipedia
{{cite web |title=Data record tests.insulation-resistance.discharge |website=Electrical Testing Reference |publisher=Electrical Testing Reference |url=https://www.electricaltestingreference.com/data/tests.insulation-resistance.discharge/ |date=2026-10-13 |access-date=}}