Data record tests.polarity-test.governed-by.ieee-c57-13-1

Verified 2026-10-13 Confidence: Medium

Provenance pending: the source of this record has not yet been confirmed as official.

Polarity Test is addressed in IEEE C57.13.1-2017.

ProvenanceIEEE C57.13.1-2017 supports data record tests.polarity-test.governed-by.ieee-c57-13-1, which is cited on the entry Polarity Test.SOURCEIEEE C57.13.1-2017IEEE C57.13.1-2017Licensed standard, clause 5.1DATA RECORDtests.polarity-test.governed-by.ieee-c57-13-1tests.polarity-test.gove..Verified 2026-10-13ENTRYPolarity TestPolarity TestNo revisions
Provenance. Where this record comes from and where it is used: the cited source, the record itself and the entry that cites it.
Provenance: the chain from source to entry.
StepItemDetail
SourceIEEE C57.13.1-2017Licensed standard, clause 5.1
Data recordtests.polarity-test.governed-by.ieee-c57-13-1Verified 2026-10-13
EntryPolarity TestNo revisions
Subject
Polarity Test (Test methods)
Kind
Method fact
Source
IEEE C57.13.1-2017, clause 5.1, Guide for Field Testing of Relaying Current Transformers, IEEE. Publisher page for IEEE C57.13.1-2017Publisher information page
Also stated in
  • FIST 4-7, section 6.1.36.1.3, page 110 (August 2023).
    Read the reference passage

    6.1.36.1.3 Current Transformer Polarity Test

    "If the polarity is correctly marked for the current transformer, the meter should show a positive or upscale "kick" when the contact is made and a negative or downside "kick" when it is broken. Current transformers must be de-magnetized following this test."

    FIST 4-7, section 6.1.36.1.3, page 110, August 2023. Agency copy of FIST 4-7

    The current standard governs; this passage is a public-domain description of the practice dated August 2023.

History

Every recorded change to this data record, oldest first.
DateChange
2026-10-13created

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Data record tests.polarity-test.governed-by.ieee-c57-13-1." Electrical Testing Reference. 2026-10-13. https://www.electricaltestingreference.com/data/tests.polarity-test.governed-by.ieee-c57-13-1/.
Electrical Testing Reference, Data record tests.polarity-test.governed-by.ieee-c57-13-1 (Oct. 13, 2026), https://www.electricaltestingreference.com/data/tests.polarity-test.governed-by.ieee-c57-13-1/.
@misc{etr-data-tests-polarity-test-governed-by-ieee-c57-13-1,
  title = {Data record tests.polarity-test.governed-by.ieee-c57-13-1},
  howpublished = {\url{https://www.electricaltestingreference.com/data/tests.polarity-test.governed-by.ieee-c57-13-1/}},
  organization = {Electrical Testing Reference},
  publisher = {Electrical Testing Reference},
  year = {2026},
  note = {last substantive change 2026-10-13}
}
{{cite web |title=Data record tests.polarity-test.governed-by.ieee-c57-13-1 |website=Electrical Testing Reference |publisher=Electrical Testing Reference |url=https://www.electricaltestingreference.com/data/tests.polarity-test.governed-by.ieee-c57-13-1/ |date=2026-10-13 |access-date=}}