Data record tests.continuity-and-shield-continuity.equipment.cable.maintenance
Verified 2026-10-13 Confidence: Medium
Provenance pending: the source of this record has not yet been confirmed as official.
Continuity and Shield Continuity is specified for shielded medium-voltage and high-voltage cables in maintenance testing at clause 7.3.3.B.3 of ANSI/NETA MTS-2023.
Value: shielded medium-voltage and high-voltage cables
| Step | Item | Detail |
|---|---|---|
| Source | ANSI/NETA MTS-2023 | Licensed standard, clause 7.3.3.B.3 |
| Data record | tests.continuity-and-shield-continuity.equipment.cable.maintenance | Verified 2026-10-13 |
| Entry | Continuity and Shield Continuity | No revisions |
- Subject
- Continuity and Shield Continuity (Test methods)
- Kind
- Equipment fact
- Source
- ANSI/NETA MTS-2023, clause 7.3.3.B.3, Maintenance Testing Specifications for Electrical Power Equipment and Systems, NETA. Publisher page for ANSI/NETA MTS-2023Publisher information page
- Also stated in
- Stated independently by TM 5-684 / NAVFAC MO-200 / AFJMAN 32-1082, section 5-29.c, PDF page 84, printed 5-17, the ellipsis drops the lead sentence of the list and the first two sentences of item (1) (29 November 1996).
Read the reference passage
5-29.c. Effectiveness of power factor tests
"This test can be performed at any voltage that does not exceed the line-to-ground voltage rating of the cable. [...] The shield should be grounded for the test only at the end where the test connections are made. An increase in power factor can indicate discontinuities or breaks in the shield."
TM 5-684 / NAVFAC MO-200 / AFJMAN 32-1082, section 5-29.c, PDF page 84, printed 5-17, the ellipsis drops the lead sentence of the list and the first two sentences of item (1), 29 November 1996. Agency copy of TM 5-684 / NAVFAC MO-200 / AFJMAN 32-1082
The current standard governs; this passage is a public-domain description of the practice dated 29 November 1996.
- Stated independently by TM 5-684 / NAVFAC MO-200 / AFJMAN 32-1082, section 5-29.c, PDF page 84, printed 5-17, the ellipsis drops the lead sentence of the list and the first two sentences of item (1) (29 November 1996).
History
| Date | Change |
|---|---|
| 2026-10-13 | created |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Data record tests.continuity-and-shield-continuity.equipment.cable.maintenance." Electrical Testing Reference. 2026-10-13. https://www.electricaltestingreference.com/data/tests.continuity-and-shield-continuity.equipment.cable.maintenance/.
Electrical Testing Reference, Data record tests.continuity-and-shield-continuity.equipment.cable.maintenance (Oct. 13, 2026), https://www.electricaltestingreference.com/data/tests.continuity-and-shield-continuity.equipment.cable.maintenance/.
@misc{etr-data-tests-continuity-and-shield-continuity-equipment-cable-maintenance,
title = {Data record tests.continuity-and-shield-continuity.equipment.cable.maintenance},
howpublished = {\url{https://www.electricaltestingreference.com/data/tests.continuity-and-shield-continuity.equipment.cable.maintenance/}},
organization = {Electrical Testing Reference},
publisher = {Electrical Testing Reference},
year = {2026},
note = {last substantive change 2026-10-13}
}{{cite web |title=Data record tests.continuity-and-shield-continuity.equipment.cable.maintenance |website=Electrical Testing Reference |publisher=Electrical Testing Reference |url=https://www.electricaltestingreference.com/data/tests.continuity-and-shield-continuity.equipment.cable.maintenance/ |date=2026-10-13 |access-date=}}