Data record tests.dc-system-ground-detection.governed-by.ieee-946

Verified 2026-10-13 Confidence: Medium

Provenance pending: the source of this record has not yet been confirmed as official.

DC System Ground Detection is addressed in IEEE 946-2020.

ProvenanceIEEE 946-2020 supports data record tests.dc-system-ground-detection.governed-by.ieee-946, which is cited on the entry DC System Ground Detection.SOURCEIEEE 946-2020IEEE 946-2020Licensed standard, clause 9.1DATA RECORDtests.dc-system-ground-detection.governed-by.ieee-946tests.dc-system-ground-d..Verified 2026-10-13ENTRYDC System Ground DetectionDC System Ground DetectionNo revisions
Provenance. Where this record comes from and where it is used: the cited source, the record itself and the entry that cites it.
Provenance: the chain from source to entry.
StepItemDetail
SourceIEEE 946-2020Licensed standard, clause 9.1
Data recordtests.dc-system-ground-detection.governed-by.ieee-946Verified 2026-10-13
EntryDC System Ground DetectionNo revisions
Subject
DC System Ground Detection (Test methods)
Kind
Method fact
Source
IEEE 946-2020, clause 9.1, Design of DC Auxiliary Power Systems for Generating Stations, IEEE. Publisher page for IEEE 946-2020Publisher information page
Also stated in
  • FIST 3-6, section 9.1, page 95 (April 2020).
    Read the reference passage

    9.1 General

    "DC systems in Reclamation are typically grounded or ungrounded depending on their application. Positive ground DC systems are often implemented on telecommunication systems (typically 48VDC) to provide cathodic protection to buried wires. Wireless communication equipment (typically 24 or 48 VDC) often utilize a negative ground. Ground faults on these grounded systems will be detected by DC overcurrent protective devices."

    FIST 3-6, section 9.1, page 95, April 2020. Agency copy of FIST 3-6

    The current standard governs; this passage is a public-domain description of the practice dated April 2020.

  • FIST 4-7, section 6.1.19.1, page 63 (August 2023).
    Read the reference passage

    6.1.19.1 Polarity (DC) Test

    "Readings between the positive and negative lead of a battery system or power supply should yield the full rated voltage, for example 24 Vdc or 125 Vdc. However, as most Reclamation dc power sources are floating, a reading of the positive or negative lead to ground can produce varying results."

    FIST 4-7, section 6.1.19.1, page 63, August 2023. Agency copy of FIST 4-7

    The current standard governs; this passage is a public-domain description of the practice dated August 2023.

History

Every recorded change to this data record, oldest first.
DateChange
2026-10-13created

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Data record tests.dc-system-ground-detection.governed-by.ieee-946." Electrical Testing Reference. 2026-10-13. https://www.electricaltestingreference.com/data/tests.dc-system-ground-detection.governed-by.ieee-946/.
Electrical Testing Reference, Data record tests.dc-system-ground-detection.governed-by.ieee-946 (Oct. 13, 2026), https://www.electricaltestingreference.com/data/tests.dc-system-ground-detection.governed-by.ieee-946/.
@misc{etr-data-tests-dc-system-ground-detection-governed-by-ieee-946,
  title = {Data record tests.dc-system-ground-detection.governed-by.ieee-946},
  howpublished = {\url{https://www.electricaltestingreference.com/data/tests.dc-system-ground-detection.governed-by.ieee-946/}},
  organization = {Electrical Testing Reference},
  publisher = {Electrical Testing Reference},
  year = {2026},
  note = {last substantive change 2026-10-13}
}
{{cite web |title=Data record tests.dc-system-ground-detection.governed-by.ieee-946 |website=Electrical Testing Reference |publisher=Electrical Testing Reference |url=https://www.electricaltestingreference.com/data/tests.dc-system-ground-detection.governed-by.ieee-946/ |date=2026-10-13 |access-date=}}