Data record tests.dielectric-withstand.governed-by.ansi-neta-ats
Verified 2026-10-13 Confidence: Medium
Provenance pending: the source of this record has not yet been confirmed as official.
Dielectric Withstand is addressed in ANSI/NETA ATS-2025.
| Step | Item | Detail |
|---|---|---|
| Source | ANSI/NETA ATS-2025 | Licensed standard, clause 7.24.1.B.11 |
| Data record | tests.dielectric-withstand.governed-by.ansi-neta-ats | Verified 2026-10-13 |
| Entry | Dielectric Withstand | No revisions |
- Subject
- Dielectric Withstand (Test methods)
- Kind
- Method fact
- Source
- ANSI/NETA ATS-2025, clause 7.24.1.B.11, Acceptance Testing Specifications for Electrical Power Equipment and Systems, NETA. Publisher page for ANSI/NETA ATS-2025Publisher information page
- Also stated in
- FIST 4-7, section 6.1.28, page 87 (August 2023).
Read the reference passage
6.1.28 Generator and Large Motor Windings
"Field windings are typically given ac high-potential tests before they are put into service."
FIST 4-7, section 6.1.28, page 87, August 2023. Agency copy of FIST 4-7
The current standard governs; this passage is a public-domain description of the practice dated August 2023.
- FIST 4-7, section 6.1.8.2, page 39 (August 2023).
Read the reference passage
6.1.8.2 High Potential Withstand Testing
"High potential (hipot) testing refers to the application of alternating, or direct, high-voltage to a test specimen for a duration of one-minute. The insulation system either passes or fails the test and is therefore categorized as a 'proof' test and does not usually provide diagnostic information. High potential withstand testing will not damage or significantly degrade an insulation system that is free of serious damage or defects."
FIST 4-7, section 6.1.8.2, page 39, August 2023. Agency copy of FIST 4-7
The current standard governs; this passage is a public-domain description of the practice dated August 2023.
- FIST 4-7, section 6.1.28, page 87 (August 2023).
History
| Date | Change |
|---|---|
| 2026-10-13 | created |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Data record tests.dielectric-withstand.governed-by.ansi-neta-ats." Electrical Testing Reference. 2026-10-13. https://www.electricaltestingreference.com/data/tests.dielectric-withstand.governed-by.ansi-neta-ats/.
Electrical Testing Reference, Data record tests.dielectric-withstand.governed-by.ansi-neta-ats (Oct. 13, 2026), https://www.electricaltestingreference.com/data/tests.dielectric-withstand.governed-by.ansi-neta-ats/.
@misc{etr-data-tests-dielectric-withstand-governed-by-ansi-neta-ats,
title = {Data record tests.dielectric-withstand.governed-by.ansi-neta-ats},
howpublished = {\url{https://www.electricaltestingreference.com/data/tests.dielectric-withstand.governed-by.ansi-neta-ats/}},
organization = {Electrical Testing Reference},
publisher = {Electrical Testing Reference},
year = {2026},
note = {last substantive change 2026-10-13}
}{{cite web |title=Data record tests.dielectric-withstand.governed-by.ansi-neta-ats |website=Electrical Testing Reference |publisher=Electrical Testing Reference |url=https://www.electricaltestingreference.com/data/tests.dielectric-withstand.governed-by.ansi-neta-ats/ |date=2026-10-13 |access-date=}}