Data record tests.visual-and-mechanical-inspection.equipment.capacitor.acceptance
Verified 2026-10-13 Confidence: Medium
Provenance pending: the source of this record has not yet been confirmed as official.
Visual and Mechanical Inspection is specified for capacitors in acceptance testing at clause 7.20.1.A of ANSI/NETA ATS-2025.
Value: capacitors
| Step | Item | Detail |
|---|---|---|
| Source | ANSI/NETA ATS-2025 | Licensed standard, clause 7.20.1.A |
| Data record | tests.visual-and-mechanical-inspection.equipment.capacitor.acceptance | Verified 2026-10-13 |
| Entry | Visual and Mechanical Inspection | No revisions |
- Subject
- Visual and Mechanical Inspection (Test methods)
- Kind
- Equipment fact
- Source
- ANSI/NETA ATS-2025, clause 7.20.1.A, Acceptance Testing Specifications for Electrical Power Equipment and Systems, NETA. Publisher page for ANSI/NETA ATS-2025Publisher information page
- Also stated in
- Stated independently by TM 5-684 / NAVFAC MO-200 / AFJMAN 32-1082, section 13-6, PDF page 144, printed 13-1, the ellipsis drops the sentence restating the IEEE 18 kilovar limit (29 November 1996).
Read the reference passage
13-6. Power capacitor inspection schedule
"The initial inspection should be made within 24 hours after energizing a new capacitor installation. This inspection should be made at a time of maximum circuit voltage, usually during the first period of light load on the circuit. In addition to visual observations, this inspection should include voltage and current readings to ensure that voltages and currents do not exceed capacitor rating limits. [...] Routine maintenance and inspection should be accomplished at least four times per year."
TM 5-684 / NAVFAC MO-200 / AFJMAN 32-1082, section 13-6, PDF page 144, printed 13-1, the ellipsis drops the sentence restating the IEEE 18 kilovar limit, 29 November 1996. Agency copy of TM 5-684 / NAVFAC MO-200 / AFJMAN 32-1082
The current standard governs; this passage is a public-domain description of the practice dated 29 November 1996.
- Stated independently by TM 5-684 / NAVFAC MO-200 / AFJMAN 32-1082, section 13-6, PDF page 144, printed 13-1, the ellipsis drops the sentence restating the IEEE 18 kilovar limit (29 November 1996).
History
| Date | Change |
|---|---|
| 2026-10-13 | created |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Data record tests.visual-and-mechanical-inspection.equipment.capacitor.acceptance." Electrical Testing Reference. 2026-10-13. https://www.electricaltestingreference.com/data/tests.visual-and-mechanical-inspection.equipment.capacitor.acceptance/.
Electrical Testing Reference, Data record tests.visual-and-mechanical-inspection.equipment.capacitor.acceptance (Oct. 13, 2026), https://www.electricaltestingreference.com/data/tests.visual-and-mechanical-inspection.equipment.capacitor.acceptance/.
@misc{etr-data-tests-visual-and-mechanical-inspection-equipment-capacitor-acceptance,
title = {Data record tests.visual-and-mechanical-inspection.equipment.capacitor.acceptance},
howpublished = {\url{https://www.electricaltestingreference.com/data/tests.visual-and-mechanical-inspection.equipment.capacitor.acceptance/}},
organization = {Electrical Testing Reference},
publisher = {Electrical Testing Reference},
year = {2026},
note = {last substantive change 2026-10-13}
}{{cite web |title=Data record tests.visual-and-mechanical-inspection.equipment.capacitor.acceptance |website=Electrical Testing Reference |publisher=Electrical Testing Reference |url=https://www.electricaltestingreference.com/data/tests.visual-and-mechanical-inspection.equipment.capacitor.acceptance/ |date=2026-10-13 |access-date=}}