Engine Generator Load and Performance

Updated 2026-10-13

RelationshipsEngine Generator Load and Performance is governed by ANSI/NETA ATS-2025, ANSI/NETA MTS-2023 and applies to no listed equipment.ANSI/NETA ATS-2025 Standard for Acceptance Testing SpecificationsANSI/NETA ATS-2025ANSI/NETA MTS-2023 Standard for Maintenance Testing SpecificationsANSI/NETA MTS-2023Engine Generator Load and PerformanceEngine Generator Load and Performa..
Relationships. Governing standards on the left, equipment classes the test applies to on the right, as recorded for this entry.
Relationships: relationships recorded for this entry.
RelationshipEntry
Governing standardANSI/NETA ATS-2025 (ANSI/NETA ATS-2025 Standard for Acceptance Testing Specifications)
Governing standardANSI/NETA MTS-2023 (ANSI/NETA MTS-2023 Standard for Maintenance Testing Specifications)

Data records

Sources

  • ANSI/NETA ATS-2025, Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2025 edition, NETA. Cited: clause 7.22.1.B.6. Held as: Purchased single-user copy. Publisher page for ANSI/NETA ATS-2025Publisher information page
  • ANSI/NETA MTS-2023, Maintenance Testing Specifications for Electrical Power Equipment and Systems, 2023 edition, NETA. Cited: clause 7.22.1.B.5. Held as: Purchased single-user copy. Publisher page for ANSI/NETA MTS-2023Publisher information page
  • Electrical Testing Reference editorial taxonomy, Electrical Testing Reference editorial taxonomy of test methods, 2026-10 edition, Electrical Testing Reference. Held as: Own observation.

Also stated in

  • Stated independently by NAVFAC MO-201, section 1.6.5.1, PDF page 34, printed 1-23, the plus-minus sign printed "+/-" as the layer reads it (April 1990).
    Read the reference passage

    1.6.5.1 Governors and Regulation

    "A governor would be set for droop only when operating in parallel (in this mode f = 60 Hz +/- 0) with a larger system or in parallel with another generator operating in the isochronous mode. In this way, system frequency is maintained and the droop adjustment controls load distribution among parallel engine generators."

    NAVFAC MO-201, section 1.6.5.1, PDF page 34, printed 1-23, the plus-minus sign printed "+/-" as the layer reads it, April 1990. Agency copy of NAVFAC MO-201

    The current standard governs; this passage is a public-domain description of the practice dated April 1990.

Obtaining the documents

Changelog (5 entries)
DateRevisionChange
2026-10-13created (tests.engine-generator-load-and-performance.equipment.generator.acceptance)
2026-10-13created (tests.engine-generator-load-and-performance.equipment.generator.maintenance)
2026-10-13created (tests.engine-generator-load-and-performance.governed-by.ansi-neta-ats)
2026-10-13created (tests.engine-generator-load-and-performance.governed-by.ansi-neta-mts)
2026-10-13created (tests.engine-generator-load-and-performance.title)

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Engine Generator Load and Performance." Electrical Testing Reference. 2026-10-13. https://www.electricaltestingreference.com/tests/engine-generator-load-and-performance/.
Electrical Testing Reference, Engine Generator Load and Performance (Oct. 13, 2026), https://www.electricaltestingreference.com/tests/engine-generator-load-and-performance/.
@misc{etr-tests-engine-generator-load-and-performance,
  title = {Engine Generator Load and Performance},
  howpublished = {\url{https://www.electricaltestingreference.com/tests/engine-generator-load-and-performance/}},
  organization = {Electrical Testing Reference},
  publisher = {Electrical Testing Reference},
  year = {2026},
  note = {last substantive change 2026-10-13}
}
{{cite web |title=Engine Generator Load and Performance |website=Electrical Testing Reference |publisher=Electrical Testing Reference |url=https://www.electricaltestingreference.com/tests/engine-generator-load-and-performance/ |date=2026-10-13 |access-date=}}