Bolted Connection Resistance
Review status: Unreviewed
Data records
- Bolted Connection Resistance is specified for automatic transfer switches in emergency systems in acceptance testing at clause 7.22.3.B.1 of ANSI/NETA ATS-2025. Value: automatic transfer switches in emergency systems.
- Bolted Connection Resistance is specified for automatic transfer switches in emergency systems in maintenance testing at clause 7.22.3.B.1 of ANSI/NETA MTS-2023. Value: automatic transfer switches in emergency systems.
- Bolted Connection Resistance is specified for direct-current system chargers in acceptance testing at clause 7.18.2.B.1 of ANSI/NETA ATS-2025. Value: direct-current system chargers.
- Bolted Connection Resistance is specified for direct-current system chargers in maintenance testing at clause 7.18.2.B of ANSI/NETA MTS-2023. Value: direct-current system chargers.
- Bolted Connection Resistance is specified for oil and vacuum automatic circuit reclosers in acceptance testing at clause 7.24.1.B.1 of ANSI/NETA ATS-2025. Value: oil and vacuum automatic circuit reclosers.
- Bolted Connection Resistance is specified for oil and vacuum automatic circuit reclosers in maintenance testing at clause 7.24.1.B.1 of ANSI/NETA MTS-2023. Value: oil and vacuum automatic circuit reclosers.
- Bolted Connection Resistance is specified for outdoor bus structures in acceptance testing at clause 7.21.B.1 of ANSI/NETA ATS-2025. Value: outdoor bus structures.
- Bolted Connection Resistance is specified for outdoor bus structures in maintenance testing at clause 7.21.B.1 of ANSI/NETA MTS-2023. Value: outdoor bus structures.
- Bolted Connection Resistance is specified for capacitors in acceptance testing at clause 7.20.1.B.1 of ANSI/NETA ATS-2025. Value: capacitors.
- Bolted Connection Resistance is specified for capacitors in maintenance testing at clause 7.20.1.B.1 of ANSI/NETA MTS-2023. Value: capacitors.
- Bolted Connection Resistance is specified for adjustable-speed drive systems in acceptance testing at clause 7.17.B.1 of ANSI/NETA ATS-2025. Value: adjustable-speed drive systems.
- Bolted Connection Resistance is specified for adjustable-speed drive systems in maintenance testing at clause 7.17.B.1 of ANSI/NETA MTS-2023. Value: adjustable-speed drive systems.
- Bolted Connection Resistance is specified for electric vehicle charging systems in maintenance testing at clause 7.26.B.1 of ANSI/NETA MTS-2023. Value: electric vehicle charging systems.
- Bolted Connection Resistance is specified for grounding systems in acceptance testing at clause 7.13.B.1 of ANSI/NETA ATS-2025. Value: grounding systems.
- Bolted Connection Resistance is specified for grounding systems in maintenance testing at clause 7.13.B of ANSI/NETA MTS-2023. Value: grounding systems.
- Bolted Connection Resistance is specified for coupling-capacitor voltage transformers in acceptance testing at clause 7.10.3.B.1 of ANSI/NETA ATS-2025. Value: coupling-capacitor voltage transformers.
- Bolted Connection Resistance is specified for coupling-capacitor voltage transformers in maintenance testing at clause 7.10.3.B.1 of ANSI/NETA MTS-2023. Value: coupling-capacitor voltage transformers.
- Bolted Connection Resistance is specified for AC induction motors and generators in acceptance testing at clause 7.15.1.B.1 of ANSI/NETA ATS-2025. Value: AC induction motors and generators.
- Bolted Connection Resistance is specified for AC induction motors and generators in maintenance testing at clause 7.15.1.B.1 of ANSI/NETA MTS-2023. Value: AC induction motors and generators.
- Bolted Connection Resistance is specified for low-voltage network protectors in acceptance testing at clause 7.8.B.1 of ANSI/NETA ATS-2025. Value: low-voltage network protectors.
- Bolted Connection Resistance is specified for low-voltage network protectors in maintenance testing at clause 7.8.B.1 of ANSI/NETA MTS-2023. Value: low-voltage network protectors.
- Bolted Connection Resistance is specified for dry-type shunt and current-limiting reactors in acceptance testing at clause 7.20.3.1.B.1 of ANSI/NETA ATS-2025. Value: dry-type shunt and current-limiting reactors.
- Bolted Connection Resistance is specified for dry-type shunt and current-limiting reactors in maintenance testing at clause 7.20.3.1.B.1 of ANSI/NETA MTS-2023. Value: dry-type shunt and current-limiting reactors.
- Bolted Connection Resistance is specified for step voltage regulators in acceptance testing at clause 7.12.1.1.B.1 of ANSI/NETA ATS-2025. Value: step voltage regulators.
- Bolted Connection Resistance is specified for step voltage regulators in maintenance testing at clause 7.12.1.1.B.1 of ANSI/NETA MTS-2023. Value: step voltage regulators.
- Bolted Connection Resistance is specified for low-voltage ground-fault protection systems in acceptance testing at clause 7.14.B.1 of ANSI/NETA ATS-2025. Value: low-voltage ground-fault protection systems.
- Bolted Connection Resistance is specified for low-voltage ground-fault protection systems in maintenance testing at clause 7.14.B of ANSI/NETA MTS-2023. Value: low-voltage ground-fault protection systems.
- Bolted Connection Resistance is specified for resistors in acceptance testing at clause 7.20.4.B.1 of ANSI/NETA ATS-2025. Value: resistors.
- Bolted Connection Resistance is specified for resistors in maintenance testing at clause 7.20.4.B.1 of ANSI/NETA MTS-2023. Value: resistors.
- Bolted Connection Resistance is specified for oil automatic line sectionalizers in acceptance testing at clause 7.24.2.B.1 of ANSI/NETA ATS-2025. Value: oil automatic line sectionalizers.
- Bolted Connection Resistance is specified for oil automatic line sectionalizers in maintenance testing at clause 7.24.2.B.1 of ANSI/NETA MTS-2023. Value: oil automatic line sectionalizers.
- Bolted Connection Resistance is specified for medium-voltage and high-voltage surge arresters in acceptance testing at clause 7.19.2.B.1 of ANSI/NETA ATS-2025. Value: medium-voltage and high-voltage surge arresters.
- Bolted Connection Resistance is specified for low-voltage surge protective devices in maintenance testing at clause 7.19.1.B.1 of ANSI/NETA MTS-2023. Value: low-voltage surge protective devices.
- Bolted Connection Resistance is specified for low-voltage air switches in acceptance testing at clause 7.5.1.1.B.1 of ANSI/NETA ATS-2025. Value: low-voltage air switches.
- Bolted Connection Resistance is specified for low-voltage air switches in maintenance testing at clause 7.5.1.1.B of ANSI/NETA MTS-2023. Value: low-voltage air switches.
- Bolted Connection Resistance is specified for switchgear and switchboard assemblies in acceptance testing at clause 7.1.1.B.1 of ANSI/NETA ATS-2025. Value: switchgear and switchboard assemblies.
- Bolted Connection Resistance is specified for liquid-filled transformers in acceptance testing at clause 7.2.2.B.1 of ANSI/NETA ATS-2025. Value: liquid-filled transformers.
- Bolted Connection Resistance is specified for liquid-filled transformers in maintenance testing at clause 7.2.2.B.1 of ANSI/NETA MTS-2023. Value: liquid-filled transformers.
- Bolted Connection Resistance is specified for small low-voltage air-cooled dry-type transformers in acceptance testing at clause 7.2.1.1.B.1 of ANSI/NETA ATS-2025. Value: small low-voltage air-cooled dry-type transformers.
- Bolted Connection Resistance is specified for small low-voltage air-cooled dry-type transformers in maintenance testing at clause 7.2.1.1.B.1 of ANSI/NETA MTS-2023. Value: small low-voltage air-cooled dry-type transformers.
- Bolted Connection Resistance is specified for uninterruptible power systems in acceptance testing at clause 7.22.2.B.1 of ANSI/NETA ATS-2025. Value: uninterruptible power systems.
- Bolted Connection Resistance is specified for uninterruptible power systems in maintenance testing at clause 7.22.2.B.1 of ANSI/NETA MTS-2023. Value: uninterruptible power systems.
- Bolted Connection Resistance is addressed in ANSI/NETA ATS-2025.
- Bolted Connection Resistance is addressed in ANSI/NETA MTS-2023.
- The test method is named Bolted Connection Resistance. Value: Bolted Connection Resistance.
Sources
- ANSI/NETA ATS-2025, Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2025 edition, NETA. Cited: clause 7.22.3.B.1; clause 7.18.2.B.1; clause 7.24.1.B.1; clause 7.21.B.1; clause 7.20.1.B.1; clause 7.17.B.1; clause 7.13.B.1; clause 7.10.3.B.1; clause 7.15.1.B.1; clause 7.8.B.1; clause 7.20.3.1.B.1; clause 7.12.1.1.B.1; clause 7.14.B.1; clause 7.20.4.B.1; clause 7.24.2.B.1; clause 7.19.2.B.1; clause 7.5.1.1.B.1; clause 7.1.1.B.1; clause 7.2.2.B.1; clause 7.2.1.1.B.1; clause 7.22.2.B.1. Held as: Purchased single-user copy. Publisher page
- ANSI/NETA MTS-2023, Maintenance Testing Specifications for Electrical Power Equipment and Systems, 2023 edition, NETA. Cited: clause 7.22.3.B.1; clause 7.18.2.B; clause 7.24.1.B.1; clause 7.21.B.1; clause 7.20.1.B.1; clause 7.17.B.1; clause 7.26.B.1; clause 7.13.B; clause 7.10.3.B.1; clause 7.15.1.B.1; clause 7.8.B.1; clause 7.20.3.1.B.1; clause 7.12.1.1.B.1; clause 7.14.B; clause 7.20.4.B.1; clause 7.24.2.B.1; clause 7.19.1.B.1; clause 7.5.1.1.B; clause 7.2.2.B.1; clause 7.2.1.1.B.1; clause 7.22.2.B.1. Held as: Purchased single-user copy. Publisher page
- Electrical Testing Reference editorial taxonomy, Electrical Testing Reference editorial taxonomy of test methods, 2026-10 edition, Electrical Testing Reference. Held as: Own observation.
Obtaining the documents
- ANSI/NETA ATS-2025: publisher catalog or sales page
- ANSI/NETA MTS-2023: publisher catalog or sales page
Changelog (47 entries)
| Date | Revision | Change | Reason | By |
|---|---|---|---|---|
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.ats-transfer.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.ats-transfer.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.battery.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.battery.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.breaker.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.breaker.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.busway.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.busway.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.capacitor.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.capacitor.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.drive.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.drive.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.evcharging.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.ground.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.ground.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.instrument.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.instrument.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.motor.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.motor.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.network-protector.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | edited (tests.bolted-connection-resistance.equipment.network-protector.acceptance) | statement regenerated from corrected seed source (prose rule 7) | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.network-protector.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | edited (tests.bolted-connection-resistance.equipment.network-protector.maintenance) | statement regenerated from corrected seed source (prose rule 7) | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.reactor.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.reactor.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.regulator.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.regulator.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.relay.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.relay.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.resistor.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.resistor.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.sectionalizer.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.sectionalizer.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.surge.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.surge.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.switch.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.switch.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.switchgear.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.transformer-fluid.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.transformer-fluid.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.transformer.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.transformer.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.ups.acceptance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.equipment.ups.maintenance) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.governed-by.ansi-neta-ats) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.governed-by.ansi-neta-mts) | seeded from the test taxonomy | agent | |
| 2026-10-13 | created (tests.bolted-connection-resistance.title) | seeded from the test taxonomy | agent |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
Plain
"Bolted Connection Resistance." Electrical Testing Reference. 2026-10-13. https://www.electricaltestingreference.com/tests/bolted-connection-resistance/.
Legal (Bluebook, internet source)
Electrical Testing Reference, Bolted Connection Resistance (Oct. 13, 2026), https://www.electricaltestingreference.com/tests/bolted-connection-resistance/.
BibTeX
@misc{etr-tests-bolted-connection-resistance,
title = {Bolted Connection Resistance},
howpublished = {\url{https://www.electricaltestingreference.com/tests/bolted-connection-resistance/}},
organization = {Electrical Testing Reference},
publisher = {Electrical Testing Reference},
year = {2026},
note = {last substantive change 2026-10-13}
} Wikipedia