Partial Discharge Online

Updated 2026-10-13

RelationshipsPartial Discharge Online is governed by ANSI/NETA ATS-2025, ANSI/NETA MTS-2023 and applies to no listed equipment.ANSI/NETA ATS-2025 Standard for Acceptance Testing SpecificationsANSI/NETA ATS-2025ANSI/NETA MTS-2023 Standard for Maintenance Testing SpecificationsANSI/NETA MTS-2023Partial Discharge OnlinePartial Discharge Online
Relationships. Governing standards on the left, equipment classes the test applies to on the right, as recorded for this entry.
Relationships: relationships recorded for this entry.
RelationshipEntry
Governing standardANSI/NETA ATS-2025 (ANSI/NETA ATS-2025 Standard for Acceptance Testing Specifications)
Governing standardANSI/NETA MTS-2023 (ANSI/NETA MTS-2023 Standard for Maintenance Testing Specifications)

Data records

Sources

  • ANSI/NETA ATS-2025, Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2025 edition, NETA. Cited: clause 7.4.B.7; clause 7.3.3.B.7; clause 11. Held as: Purchased single-user copy. Publisher page for ANSI/NETA ATS-2025Publisher information page
  • ANSI/NETA MTS-2023, Maintenance Testing Specifications for Electrical Power Equipment and Systems, 2023 edition, NETA. Cited: clause 7.4.B.7; clause 7.3.3.B.8; clause 7.20.3.1.B.5. Held as: Purchased single-user copy. Publisher page for ANSI/NETA MTS-2023Publisher information page
  • Electrical Testing Reference editorial taxonomy, Electrical Testing Reference editorial taxonomy of test methods, 2026-10 edition, Electrical Testing Reference. Held as: Own observation.

Also stated in

  • FIST 4-7, section 8.4.1.3, page 188 (August 2023).
    Read the reference passage

    8.4.1.3 Partial Discharge Test

    "Partial discharge testing is an ac test performed to establish a baseline for future tests to assess the condition of transformers and stator winding insulation. Partial discharge measurements may be performed during ac hi-pot testing during construction testing, or when the generator is energized at rated voltage as part of the startup testing, or both."

    FIST 4-7, section 8.4.1.3, page 188, August 2023. Agency copy of FIST 4-7

    The current standard governs; this passage is a public-domain description of the practice dated August 2023.

  • FIST 4-7, section 8.4.1.3, page 189 (August 2023).
    Read the reference passage

    8.4.1.3 Partial Discharge Test

    "Generator testing can be performed at full-speed isolated from the grid, synchronized no-load, low-load cold (ambient prior to the transformer or generator warming up), full-load cold, full-load hot (transformer or generator at operating temperature), and low-load hot conditions. For transformers, tests are commonly performed at low-load cold and full-load hot."

    FIST 4-7, section 8.4.1.3, page 189, August 2023. Agency copy of FIST 4-7

    The current standard governs; this passage is a public-domain description of the practice dated August 2023.

Obtaining the documents

Changelog (9 entries)
DateRevisionChange
2026-10-13created (tests.partial-discharge-online.equipment.busway.acceptance)
2026-10-13created (tests.partial-discharge-online.equipment.busway.maintenance)
2026-10-13created (tests.partial-discharge-online.equipment.cable.acceptance)
2026-10-13created (tests.partial-discharge-online.equipment.cable.maintenance)
2026-10-13created (tests.partial-discharge-online.equipment.partialdischarge.acceptance)
2026-10-13created (tests.partial-discharge-online.equipment.reactor.maintenance)
2026-10-13created (tests.partial-discharge-online.governed-by.ansi-neta-ats)
2026-10-13created (tests.partial-discharge-online.governed-by.ansi-neta-mts)
2026-10-13created (tests.partial-discharge-online.title)

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Partial Discharge Online." Electrical Testing Reference. 2026-10-13. https://www.electricaltestingreference.com/tests/partial-discharge-online/.
Electrical Testing Reference, Partial Discharge Online (Oct. 13, 2026), https://www.electricaltestingreference.com/tests/partial-discharge-online/.
@misc{etr-tests-partial-discharge-online,
  title = {Partial Discharge Online},
  howpublished = {\url{https://www.electricaltestingreference.com/tests/partial-discharge-online/}},
  organization = {Electrical Testing Reference},
  publisher = {Electrical Testing Reference},
  year = {2026},
  note = {last substantive change 2026-10-13}
}
{{cite web |title=Partial Discharge Online |website=Electrical Testing Reference |publisher=Electrical Testing Reference |url=https://www.electricaltestingreference.com/tests/partial-discharge-online/ |date=2026-10-13 |access-date=}}